Digitrax Port Devices Driver Download For Windows

Posted on  by 



Digitrax LocoNet®

  • Command Stations
  • Programmers & Adapters
  • Networking
  • Technical
Devices

Supported Hardware

Devices, command stations, networks, and protocols:

On your device, make sure you are connected to the WiThrottle server network. Start the Engine Driver app and wait for your server's address to show up in 'Discovered Servers'. Click on the discovered address, or you can enter the address and port of your WiThrottle server directly. (Using the values shown on the WiThrottle window.). Port information for various Digitrax Utilities or 3rd party software programs. If you plug your PR3 into the same physical USB Port each and every time, Windows will always assign the same COM Port to your PR3. Device Manager will show your newly installed COM port under Ports (Com & LPT). Click the Close Button 28. Oct 12, 2020 PR3 / PR4 Windows 10 Drivers.Return to Downloads. Subscribe To The Digitrax YouTube page! Join The Digitrax User Group.

  • WiFi Throttles

Applications

By the community of JMRI.org:

Tools

JMRI tools for working with your layout:
  • Common Tools:
  • Blocks:
  • Routing and Control:
  • Other:

Layout Automation

Use JMRI to automate parts of your layout and operations:

JMRI Help:
Contents/ Index
Glossary/ FAQ


The Digitrax PR3 (Xtra) can be used as a standalone decoder programmer with its own dedicated programming track (much like the Digitrax PR2), or as an interface between your computer and a LocoNet®, much like an MS100. It can only do one or the other of these at a given time. You select the PR3 operating mode in the JMRI preferences when setting up s 'connection' in the JMRI 'preferences'.

Digitrax has released a product called the 'PR3 Xtra'. This is simply a PR3 device plus a suitable power supply. It may be considered as 'identical' to a PR3 for all practical purposes.

Digitrax introduced the DCS240 device in 2016. This command station includes an integrated PR3 device. For the purposes of JMRI, the DCS240 USB interface device is equivalent to a PR3.

When the PR3 is configured to act as a programmer, it is connected to a dedicated programming track via the screw terminals on the PR3. When JMRI is properly configured, JMRI can use the PR3 programming track to set CVs in any decoder that DecoderPro supports.

It can also be used to download sound information into Digitrax sound decoders and, within its limited current capability, run one locomotive to test it. When used with Digitrax SFX decoders, 'neutral mode' allows you to vary the speed without the motor moving the decoder, so you can hear how the locomotive sound reacts to varying speeds.

Note that Digitrax only guarantees programming for Digitrax SFX decoders with properly installed loads, etc, but our testing has found that the PR3 will work with many common decoders. Digitrax port devices driver download for windows xp

When acting as an interface, the PR3 allows JMRI to interact with devices connected to LocoNet. This includes programming decoders on a programming track attached to a LocoNet command station. Where the LocoNet command station supports 'programming on the main', JMRI is able to make use of that feature.

The PR3 can also be used to connect JMRI to a 'standalone LocoNet', which may be useful when LocoNet is used for some aspects of layout control while some other control system is use for other aspects. An example may be track occupancy detection and signaling using Digitrax BDL168 and SE8C boards while locomotive control is provided by a non-LocoNet DCC system. More information on this advanced topic is available on the 'Standalone LocoNet' page.

For more information on the PR3 itself, please see the Digitrax PR3 page and the PR3 Support page.

Drivers

The PR3 needs to have a driver installed when used with Microsoft Windows. See the Digitrax PR3 Windows Setup page for more information. Make sure to follow the instructions exactly, particularly about the order of installing the drivers and plugging in the device.

Digitrax Port Devices Driver Download For Windows

See also PR3 Firmware issue which affects computers running Microsoft Windows below.

You don't need to install a separate driver when using current versions of Mac OS X or Linux.

Using the PR3 as a LocoNet Interface

To use the PR3 as an interface, connect a LocoNet cable to the LocoNet connector on the PR3. (Although not required, it's also OK to connect a power supply to the PR3). Finally, connect a USB cable between the PR3 and your computer.

Recommended setup as LocoNet interface

To set up a JMRI application to use the PR3 as an interface to a LocoNet which includes a LocoNet command station:

  • Start the program.
  • Open the Preferences window from the Edit menu and configure the connection by:
    • Select LocoNet PR3
    • Select the serial port that's connected to the PR3
    • In the 'Command Station' option, select the type of command station you've got on your LocoNet, e.g. 'DCS100 (Chief)', 'DCS050 (Zephyr)', etc.

      The 'Stand-alone LocoNet' option should be selected if you don't have a command station connected; see the 'Standalone LocoNet' page. In this case, the PR3 connection will not be able to program decoders.

    • In the advanced settings, the speed will be fixed at 57,600 baud.
    • In the advanced settings, the 'Flow Control' option defaults to 'Use Hardware Flow Control', which is the preferred setting for the PR3. You should try that first, as it is the most reliable mode. Only if you can't reliably program decoders using that choice, and only after checking that you're using the right port, should you select 'None' for this preference and try again.
  • Click Save at the bottom of the preferences window, quit the program and restart.

Using the PR3 Programming Track

To use the PR3 programming track, connect the PR3 to its power supply and to a dedicated piece of track which you'll use as the programming track. Finally, connect a USB cable between the PR3 and your computer.

Digitrax Port Devices Driver Download For Windows

Digitrax Port Devices Driver Download For Windows Xp

The PR3 does not necessarily provide reliable readback of CVs for some decoders, including many sound decoders, when the power supply is a 12VDC or 14VDC power supply. Some users repot that using a 18 VDC regulated power supply enables them to reliably read sound decoder CVs via the PR3 programming track. Do this at your own risk!Current Digitrax documentation for the PR3 defines a maximum input voltage of 15 Volts DC, where previously the maximum voltage was listed as 20 Volts DC. Use of input voltages higher than 15 Volts DC could damage the PR3 hardware.

Recommended setup as dedicated programming track

To set up a JMRI application to use the PR3 as a dedicated decoder programming track:

  • Start DecoderPro.
  • Open the Preferences window from the Edit menu and configure the connection by:
    • Select LocoNet PR3
    • Select the serial port that's connected to the PR3
    • In the 'Command Station' option, select 'PR3 Standalone Programmer'.
    • In the advanced settings, the speed will be fixed at 57,600 baud.
    • In the advanced settings, the 'Flow Control' option defaults to 'Use Hardware Flow Control', which is the preferred setting for the PR3. You should try that first, as it is the most reliable mode. Only if you can't reliably program decoders using that choice, and only after checking that you're using the right port, should you select 'None' for this preference and try again.
  • Click Save at the bottom of the preferences window, quit the program and restart.

You can use a JMRI throttle to control the locomotive connected to the PR3 Programmer. Use the JMRI Power Control or the 'Power' menu item on the Throttle's menu bar to turn on track power, and then you can operate the locomotive normally.

The PR3 can only provide very limited current, so Digitrax has built a 'neutral mode' into their sound decoders. When JMRI and the PR3 is running a Digitrax sound decoder, the motor is disconnected to reduce the current load. You can still ramp the speed up and down with the throttle and listen to how the sound responds, but the motor won't move the locomotive.

Digitrax Port Devices Driver Download For Windows 10

Digitrax port devices driver download for windows 10

Other decoders, including decoders from other manufacturers, may draw enough motor current to trip the PR3 internal circuit breakers. This will cause JMRI to mark track power as 'off'. Just wait a couple seconds and turn the track power back on to recover.

Digitrax Port Devices Driver Download For Windows 7

Using the PR3 programming track to program Non-Digitrax Decoders

To implement that 'neutral mode' described above, the PR3 automatically writes CV128 to 0 or 1. This happens when a JMRI throttle is used to run the locomotive on the PR3 programming track, and there's nothing JMRI can do to prevent it. Unfortunately, this can interfere with the CV programming on some non-Digitrax decoders. For example, it will set the 'Master Volume' CV128 on some SoundTraxx decoders to a very low volume.

See Full List On Jmri.org

If you are using the PR3 with a decoder that uses CV128 for something, you should either not use a JMRI throttle to run the locomotive on the PR3 programming track, or remember to rewrite CV128 with the right value just before removing the locomotive from the track.

Note that some PR3 devices do not behave well with JMRI when running on some versions of the Microsoft Windows computer operating systems. This problem has been seen by some some users of Windows 7 and Windows 8. These PR3s can cause erratic JMRI operation and can cause the JAVA interpreter to fail abnormally. Recovery from the issue may require re-starting JMRI or even require a true power-cycle for the computer, and this can resolve the problem until it happens again at some unpredictable future time. Note that a 'hibernation' or 'sleep' mode might not provide a temporary solution to the problem.

Digitrax has provided a PR3 firmware update which seems to resolve this issue. It may be applied by the user.

The appropriate update files and instructions are available from the 'Download' page on the Digitrax web site. Digitrax provides an application to apply the firmware update; the software package runs under Microsoft Operating Systems, and this is the strongly recommended way to apply the PR3 firmware update.

Alternatively, although not recommended for this case, JMRI provides a tool which can be used to update the PR3 firmware. The JMRI tool is not recommended for this case because the failure could happen during the JMRI firmware update process. If the failure happens during the PR3 firmware update process, it is possible that the PR3 might require factory repair.

Digitrax Port Devices Driver Download For Windows 8.1

LocoNet® is a registered trademark of Digitrax, Inc.